Longitudinal co-variation of radiographic chest-wall thickness and transcutaneous-arterial CO₂ discrepancy in congenital diaphragmatic hernia: a single-patient case study
Tomonori Kurimoto 1 2, Eiji Hirakawa 2, Hiroshi Ohashi 2, Takuya Tokuhisa 2
Affiliations Expand
- PMID: 42846408
- PMCID: PMC13644392
- DOI: 10.3389/fped.2026.1887546
Abstract
Background: Transcutaneous carbon dioxide (tcPCO₂) monitoring enables continuous non-invasive assessment of ventilation in neonates, but local tissue conditions may contribute to disagreement between tcPCO₂ and arterial PaCO₂ measurements. We explored within-patient temporal co-variation among radiographic chest-wall thickness, sensor heating power, and the discrepancy between tcPCO₂ and arterial PaCO₂ in a critically ill neonate.
Methods: We conducted an exploratory single-patient longitudinal case study over 28 days. Serial measurements of tcPCO₂, arterial PaCO₂, radiographic chest-wall thickness ratio (%skin), an unvalidated radiographic measure explored as a potential surrogate of tissue edema, sensor heating power, and daily fluid balance were evaluated. Both the signed difference (tcPCO₂-PaCO₂) and absolute difference |tcPCO₂-PaCO₂| were summarized descriptively. Temporal trajectories and within-patient associations were explored with attention to serial dependence and shared time trends.
Results: Increasing radiographic chest-wall thickness coincided with greater tcPCO₂-PaCO₂ discrepancy and higher sensor heating power. The three variables showed broadly similar rise-and-fall temporal trajectories. Unadjusted within-patient correlations were strong (r = 0.766-0.813), and residual correlations persisted but were attenuated after removal of the quadratic Day/Day2 trend (residual r = 0.545-0.625). These residual correlations were interpreted descriptively and not as evidence of a time-independent relationship. PCA identified a dominant principal component explaining 85.9% of total variance, descriptively summarizing shared temporal covariance among radiographic chest-wall thickness, sensor heating power, and tcPCO₂-PaCO₂ discrepancy.
Conclusion: In this single-patient longitudinal case study, radiographic chest-wall thickness, sensor heating power, and tcPCO₂-PaCO₂ discrepancy showed parallel temporal changes. These findings generate the hypothesis that changes in local tissue conditions associated with increased radiographic chest-wall thickness may contribute to tcPCO₂-PaCO₂ disagreement, but causal inference is not possible and validation in multi-patient studies is required.
Keywords: congenital diaphragmatic hernia; measurement discrepancy; neonates; radiographic chest-wall thickness; transcutaneous CO2.